Motor loss of power brake with DC solenoid

    Electromagnetic Power brake yoke, the armature, the connecting plate, coil springs, friction plates, gear sets, manual release mechanism and other major components, yoke mounting screws installed on the base unit or connecting plate adjustment 6 to the predetermined value of the air gap is fixed fixed coil spring mounted on the yoke, the armature can move axially inner toothing gear sleeve and the friction disc, when the coil is de-energized, under the force of the spring, friction for rent and an armature, the cradle or the interconnector frictional force is generated through the gear sets to the drive shaft brake, under the action of electromagnetic force when the coil is energized, the armature is attracted toward the yoke, to release the friction disc, the drive shaft The brake is released, in a free state.

    Brake can work reliably under the following conditions:

    1 brake installation site altitude over 2000 meters

    2 ambient temperature -5 ° C-40 ° C

    3 surrounding medium is no danger of explosion, and not enough to corrode metal and damage the insulation of gas and conductive dust

    4 brake coil voltage fluctuations do not exceed the rated voltage of +5% and -15%

    5 in dry conditions

    Brake coil supply are DC power supply, its capacity should be greater than the corresponding specifications of the brake coil power (PH) and ensure that both ends of the brake coil voltage corresponding specifications of the rated voltage (VH), motor brakes are generally in the motor terminal box with dedicated rectifier.