Motor power should be based on the requirement of eqipment and make the motor run at rated load. pay attention to the following two points: If the motor power is too small. It will result in long-term motor overload. The insulation damage due to fever. Even the motor were destroyed. If the motor power is too high. The output mechanical power can not be fully utilized, the power factor and efficiency are not high, not only detrimental to users and power grids. But also result in wasted energy.
-
When the load of the asynchronous motor is not heavy, we can achieve energy saving by reducing the outside power. If the asynchronous motor runs normally and do not take no-load torque into thinking, the electromagnetic torque must be equal to the load torque. After the power is reduced, the main flux will decrease. At this moment the motor’s torque will decrease and the motor’s rotate speed will be reduced. Although this can increase the rotor current, however, when the load of the motor is l
-
A known three-phase motor capacity, and its rated current Formula (c): kilovolt capacity divided by the number of points to take factor 76.Description:(1) formula applies to any of the three-phase voltage calculation of motor rated current.By the formula and that formula may be the same voltage capacity , rated current of different motor is not the same,that is not the same as a few kV voltage,removal of the same capacity,from quotient is clearly not the same as, Quotient is not the same by the
-
The correct installation, use and maintenance of the motor, can avoid accident and extend the using life.一 Inspection 1,Check the nameplate data Carefully, and confirm the motor is correspond with the requirements. 2, Using the 500V megohm to measuring the motor insulation resistance between winding and shell, insulation resistance should be larger than 0.5MΩ二 Installation 1,Motor usually works in the clean and dry place, the surrounding should be well-ventilated, and the highest ambient air
-
1 A symbol of protection levels is by the characterization of the letters IP and additional representation in the latter two numbersWhich the IP is the English international protection (International Protection) of the acronym.The first digitalSpecific meaningBrief0No special protectionNo protective motor1To prevent accidental or accidental human touch on or near the shell of charged or rotating parts, diameter greater than 50mm to prevent the entry of foreign matter into the solid motorSolid pr
-
When the load of the asynchronous motor is not heavy, we can achieve energy saving by reducing the outside power. If the asynchronous motor runs normally and do not take no-load torque into thinking, the electromagnetic torque must be equal to the load torque. After the power is reduced, the main flux will decrease. At this moment the motor’s torque will decrease and the motor’s rotate speed will be reduced. Although this can increase the rotor current, however, when the load of the motor is l
-
Ordinary three-phase induction motors are all designed with Constant Voltage Constant Frequency,so it is impossible for them to adapt to the frequency conversion completely.The influences that the frequency converter produces to ordinary three-phase induction motors are showed as follows: 1.the efficiency and the temperature rising of motors Frequency converters of all kinds generate sinusoidal voltage and current of different levels during the operation,which makes motors running at non-sinusoi
-
With the shortage of resources, all countries are looking for the way to save energy and develop the potential of electric energy-saving. The only way is reduce the consumption.There are many ways for motor energy saving, such as improving motor efficiency, improving power factor, adjusting speed energy saving, Frequency Controlling speed. Now we discuss lowering energy consumption on the motor power factor. Asynchronous motor power factor changes with the load. Rated load power factor is highe
-
The bearing is the most fragile part when a small or a medium-sized electric motor is running. If the bearing is damaged, circses as followed will happen: the increasing of the noise and the vibration, the rising of the working temperature, the decline of the matched equipments’precision, and it may even lead to the burning of the electric motors. So in order to extend the useful life by maintaining the bearings of electric motors, pay attention to the following factors in the course of the ins
-
1. Able to prevent from touching or approaching to the electriferous or rotating parts inside(with the exception of the smooth rotatable axletree and other similar parts),as well as to prevent the entry of foreign solid to motors.2. Prevent the entry of water to avoid the harmful effects caused by it.Second, the regulation of the protection classThe sign for the protection class: composed by the token letters “IP” and two token numbers followed. Thereinto, “IP” is the acronym of “the Intern
|
|